The fibers ,250µ m, are positioned in a loose tube made of a high modulus plastic.
Question? Click hereTechnical Informations & PricesThe fibers ,250µ m, are positioned in a loose tube made of a high modulus plastic.
The tubes are filled with a water-resistant filling compound.
A steel wire,sometimes sheathed with polyethylene (PE) for cable with high fiber count, locates in the center of core as a metallic strength member.
Tubes (and fillers) are stranded around the strength member into a compact and circular cable core.
An Aluminum Polyethylene Laminate (APL) is applied around the cable core,which is filled with the filling compound to protect it from water ingress.
then,the cable is completed with a PE sheath.Application: Duct/Aerial.
Features
• Good mechanical and temperature performance;
• High strength loose tube that is hydrolysis resistant;
• Special tube filling compound ensure a critical protection of fiber;
• Specially designed compact structure is good at preventing loose tubes from shrinking;
• PE sheath protects cable form ultraviolet radiation;
• The following measures are taken to ensure the cable watertight;
• Steel wire used as the central strength member;
• Loose tube filling compound;
• 100% cable core filling;
• APL moisture barrier
Product Mechanical performance parameter
Cable Code | Fiber Count |
Tubes | Fillers | Cable Diammeter (mm) |
Cable Weight Kg/ Km |
Tensile Strength (Long/Short term N) |
Crush Resistence (Long/Short term N/100mm) |
Bending Radius Dynamic / Static mm |
FAB-GYTA/S-2-6 | 2-6 | 1 | 4 | 8.9 | 74/88 | 600/1500 | 300/1000 | 10D/20D |
FAB-GYTA/S-8-12 | 8-12 | 2 | 3 | 8.9 | 74/88 | 600/1500 | 300/1000 | 10D/20D |
FAB-GYTA/S-20-24 | 20-24 | 4 | 1 | 8.9 | 74/88 | 600/1500 | 300/1000 | 10D/20D |
FAB-GYTA/S-38-48 | 38-48 | 4 | 1 | 9.5 | 82/97 | 600/1500 | 300/1000 | 10D/20D |
FAB-GYTA/S-62-72 | 62-72 | 6 | 0 | 10.0 | 98/114 | 600/1500 | 300/1000 | 10D/20D |
FAB-GYTA/S-86-96 | 86-96 | 8 | 0 | 11.2 | 110/129 | 600/1500 | 300/1000 | 10/20D |
FAB-GYTA/S-134-144 | 134-144 | 12 | 0 | 13.8 | 163/189 | 600/1500 | 300/1000 | 10D/20D |
Transport/Storage/Operating Temperature: – 20°C~ + 60°C
STANDARDS
Reference with Standard YD/T 901-2009 as well as IEC 60794-1
The fibers ,250µ m, are positioned in a loose tube made of a high modulus plastic.
The tubes are filled with a water-resistant filling compound.
A steel wire,sometimes sheathed with polyethylene (PE) for cable with high fiber count, locates in the center of core as a metallic strength member.
Tubes (and fillers) are stranded around the strength member into a compact and circular cable core.
An Aluminum Polyethylene Laminate (APL) is applied around the cable core,which is filled with the filling compound to protect it from water ingress.
then,the cable is completed with a PE sheath.Application: Duct/Aerial.
Features
• Good mechanical and temperature performance;
• High strength loose tube that is hydrolysis resistant;
• Special tube filling compound ensure a critical protection of fiber;
• Specially designed compact structure is good at preventing loose tubes from shrinking;
• PE sheath protects cable form ultraviolet radiation;
• The following measures are taken to ensure the cable watertight;
• Steel wire used as the central strength member;
• Loose tube filling compound;
• 100% cable core filling;
• APL moisture barrier
Product Mechanical performance parameter
Cable Code | Fiber Count |
Tubes | Fillers | Cable Diammeter (mm) |
Cable Weight Kg/ Km |
Tensile Strength (Long/Short term N) |
Crush Resistence (Long/Short term N/100mm) |
Bending Radius Dynamic / Static mm |
FAB-GYTA/S-2-6 | 2-6 | 1 | 4 | 8.9 | 74/88 | 600/1500 | 300/1000 | 10D/20D |
FAB-GYTA/S-8-12 | 8-12 | 2 | 3 | 8.9 | 74/88 | 600/1500 | 300/1000 | 10D/20D |
FAB-GYTA/S-20-24 | 20-24 | 4 | 1 | 8.9 | 74/88 | 600/1500 | 300/1000 | 10D/20D |
FAB-GYTA/S-38-48 | 38-48 | 4 | 1 | 9.5 | 82/97 | 600/1500 | 300/1000 | 10D/20D |
FAB-GYTA/S-62-72 | 62-72 | 6 | 0 | 10.0 | 98/114 | 600/1500 | 300/1000 | 10D/20D |
FAB-GYTA/S-86-96 | 86-96 | 8 | 0 | 11.2 | 110/129 | 600/1500 | 300/1000 | 10/20D |
FAB-GYTA/S-134-144 | 134-144 | 12 | 0 | 13.8 | 163/189 | 600/1500 | 300/1000 | 10D/20D |
Transport/Storage/Operating Temperature: – 20°C~ + 60°C
STANDARDS
Reference with Standard YD/T 901-2009 as well as IEC 60794-1