SXC simplex cable use single ct:>900 µ m or ct:>600 µm flame-retardant tight buffer fibre as optical communication medium,the tight buffer fibre wrapped with a layer of aramid yarn as strength member units,and the cable is completed with a PVC or LSZH (Low smoke, Zero halogen, Flame-retardant) jacket.
Question? Click hereTechnical Informations & PricesSXC simplex cable use single Ø900 μ m or Ø600 μ m flame-retardant tight buffer fibre as optical communication medium.the tight buffer fibre wrapped with a layer of aramid yarn as strength member units.and the cable is completed with a PVC orLSZH (Low smoke.Zero halogen.Flame-retardant)jacket
Features
• Tight buffer fibre ease of stripping
• Tight buffer fibre have excellent flame-retardant performance
• Aramid yarn as strength member make cable have excellent tensible strength
• The jacket anti-corrosion,anti-water,anti-ultraviolet radiation, flame-retardant and harmless to environment etc
Product Mechanical performance parameter
Cable Code |
Cable Diameter mm |
Cable weight kg/Km |
Diameter um |
Tensile Strength Long/Short term N |
Crush Resistance Long/Short term N/1000mm |
Bending Radius Dyna mic / Static mm |
|
GJFJV (H) |
Ø2.0 ± 0.2 |
3.0 |
4.0 |
900 ± 50 |
60/100 |
100/500 |
50/30 |
Ø2.0 ± 0.2 |
6.0 |
7.5 |
900 ± 50 |
80/150 |
100/500 |
50/30 |
APPLICATIONS
• Optical fibre jumper or pigtail
• Indoor riser level and plenum level cable distribution
• Interconnect between instruments,communication equipments
STANDARDS
Reference with standard YDff 1258.2-2003, ICEA-596, GR-409, IEC60794-2-10/11,etc;and meet the requirements of UL approval for OFNR and OFNP
SXC simplex cable use single Ø900 μ m or Ø600 μ m flame-retardant tight buffer fibre as optical communication medium.the tight buffer fibre wrapped with a layer of aramid yarn as strength member units.and the cable is completed with a PVC orLSZH (Low smoke.Zero halogen.Flame-retardant)jacket
Features
• Tight buffer fibre ease of stripping
• Tight buffer fibre have excellent flame-retardant performance
• Aramid yarn as strength member make cable have excellent tensible strength
• The jacket anti-corrosion,anti-water,anti-ultraviolet radiation, flame-retardant and harmless to environment etc
Product Mechanical performance parameter
Cable Code |
Cable Diameter mm |
Cable weight kg/Km |
Diameter um |
Tensile Strength Long/Short term N |
Crush Resistance Long/Short term N/1000mm |
Bending Radius Dyna mic / Static mm |
|
GJFJV (H) |
Ø2.0 ± 0.2 |
3.0 |
4.0 |
900 ± 50 |
60/100 |
100/500 |
50/30 |
Ø2.0 ± 0.2 |
6.0 |
7.5 |
900 ± 50 |
80/150 |
100/500 |
50/30 |
APPLICATIONS
• Optical fibre jumper or pigtail
• Indoor riser level and plenum level cable distribution
• Interconnect between instruments,communication equipments
STANDARDS
Reference with standard YDff 1258.2-2003, ICEA-596, GR-409, IEC60794-2-10/11,etc;and meet the requirements of UL approval for OFNR and OFNP