Indoor FTTO powered optical splitter with four terminal outputs, one cascade connection and one input. Its built-in power supply uses 220 V AC, 50/60 Hz and provides a specified electrical output of 54.5–55.5 V. Terminal compatibility, cabling and electrical loads are defined for each project.
Need a custom spec or OEM branding on this product? Talk to our engineering team.
Every batch, before shipment
Manufacturing
Custom specs and branding
Americas, Europe and Africa
The Fibramérica FTTO Powered Optical Splitter provides a distribution point between the fiber network and compatible FTTO terminals. Its six distribution ports comprise one input, one cascade connection and four terminal outputs.
The cascade connection allows the optical path to continue to another compatible distribution stage. This arrangement supports room-level and area-level fiber branches in indoor networks for offices, hotels and institutional buildings.
The unit incorporates a power supply for a compatible optical and electrical distribution system. This version is specified for 220 V AC at 50/60 Hz, with an electrical output of 54.5–55.5 V.
Terminal loads, connectors and cable arrangements are selected together. The network design must also include the optical losses of each distribution stage.
Combine the distribution layout with the Fibramérica FTTO Main Gateway and the appropriate secondary gateway format: Desktop Gateway with Wi-Fi 6 and 2.5GbE or Ceiling Gateway with Wi-Fi 6 and Gigabit Ethernet. Compatibility and power arrangements are confirmed for each project.
Include the number and location of terminals, installation voltage and proposed cable routes in your quotation request. Fibramérica can use these details to define the required equipment configuration and distribution layout.
| Specification | Details |
|---|---|
| Product type | FTTO powered optical splitter / optical outlet |
| Technical designation | 1:5 active splitter |
| Total distribution ports | 6 |
| Input ports | 1 |
| Cascade ports | 1 |
| Terminal output ports | 4 |
| Intended environment | Indoor |
| Operating wavelength | 1260–1650 nm |
| Specified optical split ratio | 85%/15% |
| Insertion loss: input to terminal outputs 1–4 | ≤16.7 dB |
| Insertion loss: input to cascade | ≤2.1 dB |
| Return loss | ≥50 dB |
| Electrical supply | 220 V AC, 50/60 Hz |
| Electrical output voltage | 54.5–55.5 V |
| Overcurrent protection | Yes |
| Overvoltage protection | Yes |
| Dimensions | 162 × 105 × 42.5 mm |
| Housing material | PC+ABS |
| Housing flame rating | UL94-V0 |
| Impact rating | IK06 |
| IP rating | IP20 |
| Operating temperature | 0 °C to +45 °C |
Terminal compatibility, connector type, cable arrangement, optical budget and allowable electrical loads must be confirmed for the selected installation. UL94-V0 is the specified housing material flame rating.
The unit has one input, one cascade connection and four terminal outputs. The designation 1:5 counts the four terminal outputs and the cascade as its five outgoing paths. The electrical supply connection is separate.
It continues the optical distribution path to another compatible stage. The network design must account for the insertion loss at each stage and the optical requirements of the connected equipment.
The unit combines optical splitting with a built-in electrical power supply for a compatible FTTO distribution system. Its specification describes optical splitting and electrical power provision; optical amplification or gain is not specified.
The specified input is 220 V AC, 50/60 Hz. A 110 V, 120 V or universal 100–240 V input is not listed. Confirm the electrical supply and the available product configuration for the installation location.
Select compatible FTTO terminals, connectors and optical or hybrid fiber-and-power cables as part of the project configuration. The specification does not declare Ethernet switch ports or IEEE 802.3af/at/bt PoE compatibility for this unit.
There are four terminal output connections. The supplied specification does not state the total power budget or maximum current per output, so the supported terminal loads and cable lengths must be confirmed for the selected installation.
The unit is specified for indoor use, with IP20 protection and an operating temperature range of 0 °C to +45 °C. Its final location and installation arrangement are defined by the project.
Our engineering team can confirm compatibility, custom specs and OEM branding options.