Modular SMC underground chamber for fiber optic networks. Dimensions: 1520 × 520 × 642 mm. B125 and C250 configurations with axial test loads of 125 kN and 250 kN.
Need a custom spec or OEM branding on this product? Talk to our engineering team.
Every batch, before shipment
Manufacturing
Custom specs and branding
Americas, Europe and Africa
The Fibramérica FAB-RS-M03 is a manhole and handhole chamber designed to protect underground fiber optic network connections, providing space for cable slack and splice closures and access for installation and maintenance. The chamber is constructed from interlocking SMC panels with transverse and vertical reinforcement, and its modular, lightweight design supports on-site assembly and manual handling. The technical specification lists B125 and C250 load-bearing configurations, both measuring 1520 × 520 × 642 mm, with axial test loads of 125 kN for B125 and 250 kN for C250 and a lateral test load of 40 kN for both. The required load-bearing grade and installation conditions should be confirmed when requesting a quotation.
| Specification | B125 | C250 |
|---|---|---|
| Model | FAB-RS-M03 | FAB-RS-M03 |
| Material | SMC | SMC |
| Size | 1520 × 520 × 642 mm | 1520 × 520 × 642 mm |
| Load-bearing grade | B125 | C250 |
| Axial test load | 125 kN | 250 kN |
| Lateral test load | 40 kN | 40 kN |
| Test | Standard | Result |
|---|---|---|
| Tensile strength | GB/T1447-2005 | 105 MPa |
| Tensile modulus | GB/T1447-2005 | 11.8 GPa |
| Bending strength | GB/T1449-2005 | 213 MPa |
| Flexural modulus | GB/T1449-2005 | 11.3 GPa |
| Impact toughness | GB/T1451-2005 | 90.8 kJ/m² |
| Barcol hardness | GB/T3854-2005 | 56 |
The datasheet reports 48-hour immersion tests in concentrated sulfuric acid, sodium hydroxide and sodium chloride. The reported results are no obvious surface corrosion and mass loss below 1%.
| Test | Standard / condition | Result |
|---|---|---|
| Heat distortion temperature | GB/T1634.2-2004(A) | 200°C |
| Bending strength | GB/T9979-2005 (-40°C) | 265 MPa |
| Flexural modulus | GB/T9979-2005 (-40°C) | 1.43 × 10⁴ MPa |
Values reproduced from the FAB-RS-M03 technical specification. Test conditions are not an operating-temperature rating.
It provides underground access and protection for fiber optic network connections, cable slack and splice closures.
The technical specification lists 1520 × 520 × 642 mm for both load-bearing configurations.
B125 and C250, with respective axial test loads of 125 kN and 250 kN. The lateral test load is 40 kN for both.
Our engineering team can confirm compatibility, custom specs and OEM branding options.